Ducted Split Unit is a highly efficient and energy saving air conditioning system that applicable to hotel, supermarket, office building, factory, entertainment lieu etc. It combines comfort of central air conditioning with flexibility of split unit. The new design considers the features of modern building, spreading cool/heating air to everywhere of the room equally, to form zero temperature difference. This model occupies less space, integrating duct and indoor decoration, become the upgrade production of central AC and traditional commercial air conditioning.
1. Wide Range, Various Type
BED indoor series provides various specifications to satisfy residential and commercial application, with electrical heater and fan coil unit, to create a comfortable environment for customer the whole year.
2. Free Application
High static pressure heads making distant air supply realized, convenient for installation. Three-speed drive.
Horizontal airflow of indoor unit, suitable for ceiling installation.
3. Low Noise, Easy Maintenance
Indoor unit can be ceiling-mounted, reducing noise to the lowest level.
High efficiency, low noise centrifugal fan motor, with sound-absorbing and heat preservation material makes low noise operation realized.
4. Intelligent Control
Advanced microcomputer control system with fully automatic control function and protection of high and low pressure, overload, voltage insufficient, phase lack and low temperature, etc.;
Error alarm and display in controller.
5. Excellent Performance
World famous components, strictly tested to match the unit. Adopting multi-blade pitch centrifugal fan coil, high efficiency compressor, controller, motor. etc. Ensure the stable operation, low vibration and noise.
Table 1
Model |
Indoor |
BED(A)21 |
BED(A)24 |
BED(A)28 |
BED(A)32 |
BED(A)36 |
|
Outdoor |
BCN(A)21 |
BCN(A)24 |
BCN(A)28 |
BCN(A)32 |
BCN(A)36 |
||
Cooling capacity |
kW |
21 |
23.8 |
27.6 |
31.4 |
35.6 |
|
Heating capacity |
kW |
23.1 |
26.2 |
30.3 |
35.4 |
40.4 |
|
Power input |
Cooling |
kW |
8.1 |
8.7 |
11.2 |
11.6 |
13.4 |
Power input |
Heating |
kW |
7.8 |
8.4 |
10.8 |
11.4 |
13.1 |
Current input |
Cooling |
A |
15.8 |
16.16 |
20.8 |
21.53 |
24.89 |
Current input |
Heating |
A |
14.9 |
15.56 |
20.1 |
21.09 |
24.23 |
Refrigerant type |
|
R410A |
|||||
Refrigerant charge amount |
Kg |
2×2.8 |
2×3.4 |
2×4.1 |
2×4.5 |
2×5.2 |
|
Connect Pipe |
Method |
|
welding |
||||
Liquid |
mm |
12.7/12.7 |
|||||
Gas |
mm |
19.05/19.05 |
|||||
Indoor unit |
Air flow |
m3/h |
4400 |
4400 |
4400 |
5800 |
6400 |
ESP |
Pa |
100 |
100 |
100 |
150 |
150 |
|
Fan |
Drive type |
|
three speed drive |
||||
Dimension |
Outdoor |
mm |
1120x830x1030 |
1180x960x1130 |
|||
Indoor |
mm |
1660x915x480 |
1660x915x480 |
||||
Power |
Outdoor |
|
380V/3Ph/50Hz |
||||
Indoor |
|
220V/1Ph/50Hz |
|||||
Noise |
Outdoor |
dB(A) |
60 |
60 |
61 |
61 |
61 |
Indoor |
dB(A) |
55 |
55 |
60 |
60 |
61 |
|
Weight |
Outdoor |
Kg |
180 |
190 |
220 |
240 |
250 |
Indoor |
Kg |
95 |
105 |
120 |
150 |
160 |
|
Condensing pipe |
|
G1 |
G1 |
G1 |
G1 |
G1 |
Table 2
Model |
Indoor |
BED(A)48 |
BED(A)62 |
BED(A)72 |
|
Outdoor |
BCN(A)48 |
BCN(A)62 |
BCN(A)72 |
||
Cooling capacity |
kW |
47.6 |
63.5 |
71.4 |
|
Heating capacity |
kW |
55.2 |
72.8 |
80.6 |
|
Power input |
Cooling |
kW |
17.7 |
24.1 |
26.3 |
Power input |
Heating |
kW |
17.5 |
23.3 |
25.5 |
Current input |
Cooling |
A |
32.79 |
44.74 |
48.82 |
Current input |
Heating |
A |
32.37 |
43.23 |
47.26 |
Refrigerant type |
|
R410A |
|||
Refrigerant charge amount |
Kg |
9+4.5 |
2×9.5 |
2×10.5 |
|
Connect Pipe |
Method |
|
welding |
||
Liquid |
mm |
12.7/15.88 |
15.88/15.88 |
15.88/15.88 |
|
Gas |
mm |
19.05/28 |
28/28 |
28/28 |
|
Indoor unit |
Air flow |
m3/h |
8700 |
11640 |
13000 |
ESP |
Pa |
200 |
300 |
300 |
|
Fan |
Drive type |
|
single speed drive |
||
Dimension |
Outdoor |
mm |
1640x880x1130 |
1840x970x1130 |
2120x970x1130 |
Indoor |
mm |
2065x1160x680 |
1870x1230x980 |
1870x1230x1080 |
|
Power |
Outdoor |
|
380V/3Ph/50Hz |
||
Indoor |
|
380V/3Ph/50Hz |
|||
Noise |
Outdoor |
dB(A) |
67 |
67 |
68 |
Indoor |
dB(A) |
63 |
65 |
66 |
|
Weight |
Outdoor |
Kg |
280 |
340 |
460 |
Indoor |
Kg |
200 |
230 |
300 |
|
Condensing pipe |
|
G1 |
G1 |
G1 |
Notes:
1. Cooling conditioning: Indoor temperature DB: 27 ℃, WB: 19 ℃; outdoor temperature DB: 35 ℃,WB: 24 ℃.