4 Way Cassette Fan Coil Unit

122343454556 app

The fan coil unit is a terminal unit for chilled water and hot water system, such as air cooled and heat pump or water cooled water chiller and heat pump. It mainly consists of fan, cooling coil and casing.

This 4 way cassette fan coil unit is normally installed under the ceiling and supply cool or hot air to wide space with its swings.

fea

4 Way air flow, even temperature distribution

 1231

Slim body can be installed in limited space ( Minimum thickness is 260mm)

Remote controller is standard device, wired controller is optional.

 13 2134214

Auto swing

Quiet running

Using advanced 3D software to design the centrifugal fan with stream line and big diameter  turbine.

The efficiency of airflow rate, heavy wind volume and low noise is excellent, as the ventilator wheel is processed to sine strip seam, which enhances its flexibility, and drops the vibration of ventilator during revolving in large scale, simultaneously reduced the motor noise caused by ventilator swinging.

24342
Quiet running

Using advanced 3D software to design the centrifugal fan with stream line and big diameter  turbine.

The efficiency of airflow rate, heavy wind volume and low noise is excellent, as the ventilator wheel is processed to sine strip seam, which enhances its flexibility, and drops the vibration of ventilator during revolving in large scale, simultaneously reduced the motor noise caused by ventilator swinging.

3212312 12313

Fresh air can be input from outside

Fresh air inlet can intake some fresh air from outside and ensure the indoor air quality.  The user can share the fresh and clean air to lessen illness caused by air conditioner.

 23344

The water remain in the tray is easy to be drained by manual.

There is a rubber plug on the tray, dirty water can be drained manually. As the water remained inside of the tray will be kept for long time, it will be very dirty and lots of bacterial inside as well, it’s good to drain out the dirty water for healthy and avoid possible pump blocking.

 ”C” type heat exchanger, blue hydrophilic fin

 23154

Fan and fan motor is easy to maintain

After take out the air grid to the panel, the electric box an be easily taken out, as well as fan and fan motor.

 23523

Square panel, the water inlet/outlet connection direction can be chosen freely

Corner cover design makes installation and maintenance convenient.

 324523543

590*590mm dimension model, can be installed in a standard ceiling opening.

 2132543

op

Negative ion generator  

Easily interfaced with most widely used Modbus and BMS.

4654

Water valve can be installed inside of the unit

Water valve is used to control the on/off water flowing to the unit, we install the valve into the unit, so the users do not need to install it by themselves.

3254235

Stainless steel hose can be installed to the unit and act as the inlet/outlet water connection of the unit

Stainless steel hose is used to reduce the vibration of the water pipe, big vibration may cause pipe broken or leakage, we install the stainless steel hose inside of the unit, so the user do not need to install it again, will reduce the possible leakage as well.

2142342

4 tubes system

There are both cooling and heating water coils inside the unit, so the unit can deal with cooling or heating at the same time.

76878967579 se

Table 1  

Model

Unit

BCF34K

BCF51K

BCF68K

BCF80K

BCF85K

BCF102K

Power supply

220V, 1Ph, 50Hz

Air flow rate

H

m3/h

380

550

680

780

880

1050

M

300

440

540

620

700

840

L

230

330

410

470

530

630

ESP

Pa

0

0

0

0

0

0

Cooling capacity

TH

H

W

2000

3000

3800

4200

4900

5800

SH

W

1400

2200

2850

3300

3500

4250

TH

M

W

1700

2550

3250

3550

4150

4950

SH

W

1150

1800

2350

2650

2850

3500

TH

L

W

1400

2050

2600

2900

3400

4000

SH

W

950

1400

1850

2100

2300

2800

Heating capacity

H

W

3100

4700

5900

6500

7600

9000

M

W

2650

4000

5000

5550

6450

7650

L

W

2100

3150

3950

4350

5100

6050

Noise

High speed

dB(A)

38

40

42

44

42

44

Power input

W

40

50

58

60

70

95

water flow

m3/h

0.34

0.51

0.65

0.72

0.83

0.99

Pressure drop

KPa

11

13

22

25

18

25

Water inlet pipe

inch

ZG3/4″

ZG3/4″

ZG3/4″

ZG3/4″

ZG3/4″

ZG3/4″

Water outlet pipe

inch

ZG3/4″

ZG3/4″

ZG3/4″

ZG3/4″

ZG3/4″

ZG3/4″

Coil type

 

Cu/Al

Cu/Al

Cu/Al

Cu/Al

Cu/Al

Cu/Al

Max. working pressure

MPa

1.6

1.6

1.6

1.6

1.6

1.6

Drain pipe dia.

mm

φ26

φ26

φ26

φ26

φ26

φ26

Unit Dimension

L

mm

590

590

590

590

750

750

W

mm

590

590

590

590

750

750

H

mm

242

242

242

242

242

242

Panel Dimension

L

mm

650

650

650

650

850

850

W

mm

650

650

650

650

850

850

H

mm

40

40

40

40

40

40

Net weight

kg

19.2

20.2

20.2

20.7

26.2

27.2

Table 2

Notes:

1. Cooling standard condition: Inlet air DB temp. 27℃, WB temp. 19.5℃, water inlet temp. 7 ℃, water outlet temp. 12℃.

2. Heating standard condition: Inlet air DB 21℃,  water inlet temp.60 ℃.