The fan coil unit is a terminal unit for chilled water and hot water system, such as air cooled and heat pump or water cooled water chiller and heat pump. It mainly consists of fan, cooling coil and casing.
This 4 way cassette fan coil unit is normally installed under the ceiling and supply cool or hot air to wide space with its swings.
4 Way air flow, even temperature distribution
Slim body can be installed in limited space ( Minimum thickness is 260mm)
Remote controller is standard device, wired controller is optional.
Auto swing
Fresh air can be input from outside
Fresh air inlet can intake some fresh air from outside and ensure the indoor air quality. The user can share the fresh and clean air to lessen illness caused by air conditioner.
The water remain in the tray is easy to be drained by manual.
There is a rubber plug on the tray, dirty water can be drained manually. As the water remained inside of the tray will be kept for long time, it will be very dirty and lots of bacterial inside as well, it’s good to drain out the dirty water for healthy and avoid possible pump blocking.
”C” type heat exchanger, blue hydrophilic fin
Fan and fan motor is easy to maintain
After take out the air grid to the panel, the electric box an be easily taken out, as well as fan and fan motor.
Square panel, the water inlet/outlet connection direction can be chosen freely
Corner cover design makes installation and maintenance convenient.
590*590mm dimension model, can be installed in a standard ceiling opening.
Negative ion generator
Easily interfaced with most widely used Modbus and BMS.
Water valve can be installed inside of the unit
Water valve is used to control the on/off water flowing to the unit, we install the valve into the unit, so the users do not need to install it by themselves.
Stainless steel hose can be installed to the unit and act as the inlet/outlet water connection of the unit
Stainless steel hose is used to reduce the vibration of the water pipe, big vibration may cause pipe broken or leakage, we install the stainless steel hose inside of the unit, so the user do not need to install it again, will reduce the possible leakage as well.
4 tubes system
There are both cooling and heating water coils inside the unit, so the unit can deal with cooling or heating at the same time.
Table 1
Model |
Unit |
BCF34K |
BCF51K |
BCF68K |
BCF80K |
BCF85K |
BCF102K |
||
Power supply |
220V, 1Ph, 50Hz |
||||||||
Air flow rate |
H |
m3/h |
380 |
550 |
680 |
780 |
880 |
1050 |
|
M |
300 |
440 |
540 |
620 |
700 |
840 |
|||
L |
230 |
330 |
410 |
470 |
530 |
630 |
|||
ESP |
Pa |
0 |
0 |
0 |
0 |
0 |
0 |
||
Cooling capacity |
TH |
H |
W |
2000 |
3000 |
3800 |
4200 |
4900 |
5800 |
SH |
W |
1400 |
2200 |
2850 |
3300 |
3500 |
4250 |
||
TH |
M |
W |
1700 |
2550 |
3250 |
3550 |
4150 |
4950 |
|
SH |
W |
1150 |
1800 |
2350 |
2650 |
2850 |
3500 |
||
TH |
L |
W |
1400 |
2050 |
2600 |
2900 |
3400 |
4000 |
|
SH |
W |
950 |
1400 |
1850 |
2100 |
2300 |
2800 |
||
Heating capacity |
H |
W |
3100 |
4700 |
5900 |
6500 |
7600 |
9000 |
|
M |
W |
2650 |
4000 |
5000 |
5550 |
6450 |
7650 |
||
L |
W |
2100 |
3150 |
3950 |
4350 |
5100 |
6050 |
||
Noise |
High speed |
dB(A) |
38 |
40 |
42 |
44 |
42 |
44 |
|
Power input |
W |
40 |
50 |
58 |
60 |
70 |
95 |
||
water flow |
m3/h |
0.34 |
0.51 |
0.65 |
0.72 |
0.83 |
0.99 |
||
Pressure drop |
KPa |
11 |
13 |
22 |
25 |
18 |
25 |
||
Water inlet pipe |
inch |
ZG3/4″ |
ZG3/4″ |
ZG3/4″ |
ZG3/4″ |
ZG3/4″ |
ZG3/4″ |
||
Water outlet pipe |
inch |
ZG3/4″ |
ZG3/4″ |
ZG3/4″ |
ZG3/4″ |
ZG3/4″ |
ZG3/4″ |
||
Coil type |
|
Cu/Al |
Cu/Al |
Cu/Al |
Cu/Al |
Cu/Al |
Cu/Al |
||
Max. working pressure |
MPa |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
||
Drain pipe dia. |
mm |
φ26 |
φ26 |
φ26 |
φ26 |
φ26 |
φ26 |
||
Unit Dimension |
L |
mm |
590 |
590 |
590 |
590 |
750 |
750 |
|
W |
mm |
590 |
590 |
590 |
590 |
750 |
750 |
||
H |
mm |
242 |
242 |
242 |
242 |
242 |
242 |
||
Panel Dimension |
L |
mm |
650 |
650 |
650 |
650 |
850 |
850 |
|
W |
mm |
650 |
650 |
650 |
650 |
850 |
850 |
||
H |
mm |
40 |
40 |
40 |
40 |
40 |
40 |
||
Net weight |
kg |
19.2 |
20.2 |
20.2 |
20.7 |
26.2 |
27.2 |
Table 2
Notes:
1. Cooling standard condition: Inlet air DB temp. 27℃, WB temp. 19.5℃, water inlet temp. 7 ℃, water outlet temp. 12℃.
2. Heating standard condition: Inlet air DB 21℃, water inlet temp.60 ℃.