China Cheap price Water Cooled Air Condition Water Chiller - 1 Way Cassette Fan Coil Unit – Bueco

213213421 app

The fan coil unit is a terminal unit for chilled water and hot water system, such as air cooled and heat pump or water cooled water chiller and heat pump. It mainly consists of fan, cooling coil and casing.

This 1 way cassette fan coil unit is normally installed under the ceiling and supply cool or hot air to wide space with its swings.

fea

1. One Way air flow, which is easy to be installed in the side of ceiling

2. Slim body can be installed in limited space ( Body thickness is 235mm)

3421

3. Remote controller is standard device, wired controller is optional.

 13

4. Auto swing, wide air flowing range, air flowing height up to 3.5m, air delivery angle up to 50o.

 1231

5. Horizontal air diffuser can be adjusted by manual.

 23213

6. Quiet running

Using double axial extension fan, operation is more stable.

   213 31

High lift water drained pump (750mm), easy to plan the condensed water drain pipe. 

7. Water level switch inside to keep away leakage

After the water raising to a certain position, the float switch will act and alarm, then the unit will cut off the water valve or stop the fan motor.

3212312 12313

8. Fresh air can be input from outside

Fresh air inlet can intake some fresh air from outside and ensure the indoor air quality.  The user can share the fresh and clean air to lessen illness caused by air conditioner.

 3123

9. Easy installation, low installation cost

No air ducting required, comparing with concealed duct fan coil unit.

10. Fan and fan motor is easy to maintain

op1.Negative ion generator  

321

2.Easily interfaced with most widely used Modbus and BMS.

4654

3. The water inlet/outlet connection direction (left or right) can be customized.

 0980978

 

4.To distinguish t

he water inlet/water outlet pipe of the fan coil unit, will reduce the working hours of piping layout and optimize the space.

5.Water valve can be installed inside of the unit

Water valve is used to control the on/off water flowing to the unit, we install the valve into the unit, so the users do not need to install it by themselves.

6.4 tubes system

There are both cooling and heating water coils inside the unit, so the unit can deal with cooling or heating at the same time.

76878967579

se

Table 1 (1 way cassette fan coil unit, 2 pipes type)

Model

Unit

BCF34K1

BCF51K1

BCF68K1

BCF85K1

Power supply

220V, 1Ph, 50Hz

Air flow rate

H

m3/h

340

510

680

850

M

280

380

515

660

L

180

260

340

430

ESP

Pa

0

0

0

0

Cooling capacity

TH

H

W

1800

2700

3600

4500

SH

W

1300

1970

2700

3184

TH

M

W

1500

2460

3000

3715

SH

W

1000

1555

1995

2420

TH

L

W

1390

2057

2479

2920

SH

W

823

1200

1530

1825

Heating capacity

H

W

2700

4050

5400

6750

M

W

1950

2770

3935

4900

L

W

1290

1774

2800

3505

Noise

High speed

dB(A)

37

39

41

43

Power input

W

37

52

62

76

water flow

m3/h

0.31

0.46

0.62

0.77

Pressure drop

kPa

10.8

10.8

20

20

Water inlet pipe

inch

ZG3/4″

ZG3/4″

ZG3/4″

ZG3/4″

Water outlet pipe

inch

ZG3/4″

ZG3/4″

ZG3/4″

ZG3/4″

Coil type

 

Cu/Al

Cu/Al

Cu/Al

Cu/Al

Max. working pressure

MPa

1.6

1.6

1.6

1.6

Drain pipe dia.

mm

φ26

φ26

φ26

φ26

Unit Dimension

L

mm

971

971

971

971

W

mm

413

413

413

413

H

mm

236

236

236

236

Panel Dimension

L

mm

1044

1044

1044

1044

W

mm

468

468

468

468

H

mm

31

31

31

31

Net weight

kg

26

26

27

27

Table 2 (1 way cassette fan coil unit, 4 pipes type)

Model

Unit

BCF136K1/4

BCF153K1/4

BCF170K1/4

BCF204K1/4

Power supply

220V, 1Ph, 50Hz

Air flow rate

H

m3/h

340

510

680

850

M

280

380

515

660

L

180

260

340

430

ESP

Pa

0

0

0

0

Cooling capacity

TH

H

W

1350

2030

2700

3380

SH

W

1000

1520

2080

2450

TH

M

W

1130

1850

2250

2790

SH

W

770

1200

1540

1860

TH

L

W

1040

1540

1860

2190

SH

W

630

920

1180

1410

Heating capacity

H

W

1080

1620

2160

2700

M

W

780

1108

1574

1960

L

W

516

710

1120

1402

Noise

High speed

dB(A)

43

44

45

46

Power input

W

45

60

75

85

water flow rate (cooling pipe) (H)

m3/h

0.23

0.35

0.46

0.58

water flow rate (Heating pipe) (H)

m3/h

0.09

0.14

0.19

0.23

Pressure drop

Cooling pipe

kPa

20

20

20

20

Heating pipe

kPa

10

10

10

10

Cooling water pipe size

inch

ZG3/4″

ZG3/4″

ZG3/4″

ZG3/4″

Heating water pipe size

inch

ZG1/2″

ZG1/2″

ZG1/2″

ZG1/2″

Coil type

 

Cu/Al

Cu/Al

Cu/Al

Cu/Al

Max. working pressure

MPa

1.6

1.6

1.6

1.6

Drain pipe dia.

mm

φ26

φ26

φ26

φ26

Unit Dimension

L

mm

958

958

958

958

W

mm

413

413

413

413

H

mm

236

236

236

236

Panel Dimension

L

mm

1044

1044

1044

1044

W

mm

468

468

468

468

H

mm

31

31

31

31

Net weight

kg

25

25

26

26

Notes:

1. Cooling standard condition: Inlet air DB temp. 27℃, WB temp. 19.5℃, water inlet temp. 7 ℃, water outlet temp. 12℃.

2. Heating standard condition: Inlet air DB 21℃,  water inlet temp.60 ℃.


  • China Cheap price Water Cooled Air Condition Water Chiller - 1 Way Cassette Fan Coil Unit – Bueco Related Video:

    WhatsApp Online Chat !